• Fast raising and lowering time.
  • Ideal for car parks, traffic control and high security areas, where there is a risk of vehicle attack or vandalism.
  • These road blockers are robust, safe and can be installed in any road surface.


Technical Specifications:

GENERAL DESCRIPTION:

Height      300 mm
Width     500 mm
Axle load in position    200 kN (class 60)
Impact  200 kN at a speed of 80 km/h by a vehicle of 40 ton

 

CONSISTS OF:

Foundation Frame angular profile 200 x 200 UNP
Blocking element box profile 200 x 200 UNP
Front plate 10 mm
 Top section plate durbar plate 8/10 mm
Surface treatment  shot-blasted SA 2.5 Metalised, galvanized, 2 layers of powder coating, + 80 um per layer
Colours RAL 9005 (black), Yellow stripes so called “chevrons” RAL 1023, Other Colours at request

  

JUNCTION BOX:

Junction Box The junction box can be connected with:
  • Feed cable from the control cabinet

  • control current from the control cabinet

  • limit switches

  • motor by shielded cable mounting position in foundation frame

End/limit detection 2 inductive limit switches 24 VDC, normally open in opened and closed position the drive is equipped with a mechanical emergency end stop.
Main switch      3-phase main switch installed in foundation frame (only electrical Blockers).

                   

HYDRAULIC DRIVE:

Motor specifications 
  • 230-400 VAC, 50 Hz 30 Amp supply IP 54
  • Oil content 60 leter
  • 1.5 bar
  • 800 x 500 x 700 (h x w x l), or integrated in the Blocker or within 3 meters distance next to the Blocker + 80 dB at 1 meter distance.
  •  Standard capacity 3kW (depends on the width of the element and the required speed)  (+ 2.5=>5kW) control current valves 220 VAC
  • Motor must be protected against overload by controls (optional)
Temperature the system will withstand an environmental temperature of –20 C/+70 C
Opening/closing time 3-4 sec.
Hydro unit maximum 15 m due to pressure losses in the pipes (in case of steel pipes are used)
Quantity cylinders width = 5000: 2 cylinder
Axle load   standard 10 kN   optional heavier axle load            
Cylinder buffing in the    position and hydro-unit to be max. 3-meter distance (standard)   during mounting the pipes need to be correctly preserved (epoxy coating)
Oil  type Hvi iso VG 46
Manual override emergency value (point 11)  the Blocker can only be driven in the position through it’s own weight, ,the emergency value at the power pack can be used manually.

 

CONTROLS (OPTION):

A Control Cabinet is required. A control Cabinet is a separate lockable cabinet (steel plate) where various drive Possibilities can be connected. This Control Cabinet will be installed in security Area or guard house and provided with push button controls. The Control Cabinet type 11 (1O66, RAL 7032) includes:

  • PLC – control (FX0-40MR-ES)

  • Wall outlet

  • Main switch

  • Circuit breaker

  • DC power supply

  • Connection strip

 Measurements steel plate cabinet                         : 600 x 600 x 200 mm (w x h x d)