| Technical
Specifications: |
GENERAL
DESCRIPTION:
| Height
|
300
mm |
| Width
|
500
mm |
| Axle
load in position |
200
kN (class 60) |
| Impact
|
200
kN at a speed of 80 km/h by a vehicle of 40
ton |
CONSISTS OF:
| Foundation Frame |
angular profile 200 x 200 UNP |
| Blocking
element |
box
profile 200 x 200
UNP |
| Front
plate |
10
mm |
| Top
section plate |
durbar
plate 8/10 mm |
| Surface
treatment |
shot-blasted
SA 2.5
Metalised, galvanized,
2 layers of powder
coating, + 80 um per layer |
| Colours |
RAL
9005 (black),
Yellow stripes so called
“chevrons” RAL 1023,
Other
Colours at request |
JUNCTION BOX:
| Junction
Box |
The
junction box can be connected with:
-
Feed
cable from the control cabinet
-
control
current from the control cabinet
-
limit
switches
-
motor
by shielded cable mounting position in foundation frame
|
| End/limit
detection |
2
inductive limit switches 24 VDC, normally
open in opened and closed
position the drive is
equipped with a
mechanical emergency
end
stop. |
| Main
switch |
3-phase
main switch installed in foundation
frame
(only electrical Blockers). |
HYDRAULIC DRIVE:
| Motor specifications
|
- 230-400
VAC, 50
Hz 30 Amp supply IP
54
- Oil
content 60 leter
- 1.5
bar
- 800
x 500 x 700 (h x w x l), or integrated in the Blocker or within 3 meters distance next to the Blocker + 80 dB at 1
meter distance.
- Standard capacity 3kW (depends on the width of the element and the
required speed)
(+ 2.5=>5kW) control current valves 220 VAC
- Motor must be protected against overload by controls (optional)
|
| Temperature |
the
system will withstand an environmental
temperature
of –20 C/+70 C |
| Opening/closing
time |
3-4 sec. |
| Hydro
unit |
maximum
15 m due to pressure losses in
the
pipes (in case of steel
pipes are used) |
| Quantity
cylinders |
width
= 5000: 2 cylinder |
| Axle
load |
standard
10 kN optional heavier axle load |
| Cylinder
|
buffing
in the position
and hydro-unit to be max.
3-meter distance
(standard)
during mounting the pipes need to be correctly
preserved (epoxy coating) |
| Oil
|
type
Hvi iso VG 46 |
| Manual
override |
emergency
value (point 11) the
Blocker can only be driven in the
position
through it’s own weight, ,the emergency value
at the power pack can be used manually. |
CONTROLS
(OPTION):
A
Control Cabinet
is required.
A control Cabinet is a separate
lockable cabinet (steel plate) where various drive Possibilities
can be connected. This Control Cabinet will be installed in security Area
or guard house and provided with push button controls.
The Control Cabinet type
11 (1O66, RAL 7032) includes:
Measurements
steel plate cabinet
: 600 x 600 x 200 mm (w x h x d)
|